Grease trap maintenance: daily habits, pump-outs, additives and records
Last updated .
What restaurants have to do between pump-outs and on pump-out day, according to the cities that enforce it. It covers the kitchen habits the Houston, Austin and Southlake guides recommend, when to pump, what a proper interceptor cleaning includes, the rules on enzymes and hot water, and which records to keep. Every rule links to its source.
What does grease trap maintenance involve?
Grease trap maintenance has two parts. Between pump-outs, the kitchen keeps grease and food solids out of the drains: scrape plates dry, use sink and floor-drain strainers, recycle fryer oil and never pour grease down a drain. On schedule, a city-permitted hauler pumps the whole trap, usually at least every 90 days, and leaves a manifest.
Grease trap maintenance checklist
Built only from the city sources cited on each line. Your own city’s rule wins where it differs; open your city page to check.
Every shift
- Scrape or dry-wipe food and solidified grease from pots, pans, fryers, utensils, screens and mats into the trash before washing.[1][2]
- Keep removable strainers on all kitchen sinks and floor drains, and empty them often.[1][2]
- Pour used cooking oil and grease into a covered container for recycling, and don’t overfill the bin.[1]
- Clean spills with dry methods; don’t hose grease or food waste into drains, streets or gutters.[2]
- If you have a hydromechanical (small, often indoor) interceptor, Southlake says to inspect it each day of operation.[3]
Every pump-out
- Use a hauler permitted by your city, and check the truck against the city list.[1][2]
- Be present. Ask the hauler how much of the trap was grease and solids, and about the condition of the trap.[2][1]
- Make sure every compartment is emptied and nothing is pumped back in.[3][4]
- Fill in the generator part of the manifest before the waste leaves, and keep your copy.[1]
- If the manifest says the trap needs repair, have it fixed right away.[2]
Regularly
- Check that lids aren’t blocked, bolts aren’t seized and covers aren’t damaged.[2]
- Give staff refresher training and keep no-grease signs posted.[1]
- Clean hood filters and dispose of that grease properly, not on the roof or in a storm drain.[1] See restaurant hood cleaning rules.
- Fix slow drains, backups and leaks promptly.[2]
How often should a grease trap be pumped?
Most cities here set a 90-day minimum, and some add a fullness trigger; pump at whichever comes first. Dallas and Irving require pumping sooner at 25 percent of the wetted height, and Austin at 50 percent. Grand Prairie sets monthly or quarterly service by food type, and Miami-Dade writes 30 to 90 days into each permit.
| City | Pump-out minimum | Additives and enzymes | Keep records |
|---|---|---|---|
| Houston, TX | At least every 90 days, or more often as needed, by a permitted transporter.[1] | Surfactants, solvents and emulsifiers may not be discharged to the interceptor. Inspectors ask for invoices from a permitted biological pretreatment company, if you use one.[1][9] | 5 years (white and yellow manifest copies).[1] |
| Austin, TX | At least every 90 days, or sooner at 50 percent of the wetted height (§ 15-10-197).[2] | Never use enzymes, bacteria or other agents that make grease pass through the trap (§ 15-10-22(23)).[2] | 3 years (§ 15-10-165).[2] |
| Dallas, TX | 100 percent pumped every 90 days, or sooner at 25 percent of the wetted height.[5] | Not stated in the sources we cite. | City trip ticket for every load.[10] |
| Fort Worth, TX | 100 percent pumped at least every 90 days, and as needed.[11] | No enzymes, bacteria or other bioremediation products without city approval (Sec. 12.5-731). Hot-water flushing instead of pumping is on the city’s don’t list.[11] | 5 years (final trip ticket).[11] |
| Irving, TX | Every 90 days, or sooner at 25 percent of the wetted height (Sec. 41-50). Traps under 500 gallons more often.[6][12] | Bacteria or enzyme treatments are not allowed in place of proper maintenance.[12] | 5 years (ordinance).[6] |
| Plano, TX | Completely evacuated every 90 days, or sooner at 25 percent after written notice (Sec. 21-362).[13] | No enzymes, bacteria or other additives without the Director’s approval.[13] | 3 years.[13] |
| Southlake, TX | Every 90 days for restaurants; the manual recommends cleaning hydromechanical units more often and uses a 25 percent rule of thumb.[14][3] | Emulsifying additives banned. Non-emulsifying biological additives need a safety data sheet sent to Public Works first, and the trap should still be inspected monthly.[3] | 3 years.[3] |
| North Richland Hills, TX | At least every three months by a city-permitted vehicle.[15] | Not stated in the sources we cite. | 2 years.[15] |
Grand Prairie, Rowlett, New Orleans and Miami-Dade schedules are on their city pages: Grand Prairie, Rowlett, New Orleans, Miami, Nashville, Tampa, Jacksonville, Cincinnati, Louisville, Broward County, Hampton Roads, Pinellas County, Gainesville, Baton Rouge, Corpus Christi, Bradenton, Denton, Brownsville, Tulsa, McAllen, Oklahoma City, Williamsburg, Charleston. “Wetted height” is measured from the bottom of the trap to the invert of the outlet pipe.[2][5]
The U.S. EPA says kitchens that follow best management practices can often cut how often their trap needs service.[16] Southlake says the same about its BMPs.[3] That can mean a fuller trap gets pumped less often than a neglected one, but no city here lets you go past its minimum.
What should kitchen staff do every day to keep the grease trap working?
The Houston, Austin and Southlake guides list the same habits. Scrape or dry-wipe pots, plates and fryers into the trash before washing. Put removable strainers on sinks and floor drains. Pour used cooking oil into a covered recycling container. Sweep before mopping, clean spills dry, post no-grease signs, and train staff with regular refreshers.
- Dry first, then wash. Southlake explains why: wet methods wash grease into drains, where it collects on the inside of the pipes.[3] Austin discourages cloth towels because they release grease when washed, and suggests paper towels.[2]
- No food grinders. Austin has prohibited food grinders and garbage disposals in commercial kitchens in its service area since 2008.[2] Southlake strongly discourages them and does not allow them on a hydromechanical interceptor.[3]
- Keep the wrong things out. Austin lists food waste, grease, oils, dairy products, chemicals and cleaning solutions as things not to put into sinks, floor drains, toilets or storm drains.[2]
- Store oil safely. Austin says to store oil, grease and waste containers with secondary containment.[2] Houston warns that overfilled oil bins attract rodents.[1] More on collectors: used cooking oil pickup.
- Capture mat and hood grease. Southlake says to capture grease from cleaning mats and exhaust hoods and dispose of it properly, never in a sink or outside drain.[3]
What should a grease interceptor cleaning include?
A full pump-out, not a skim. Southlake requires every chamber left completely empty, with the grease mat, liquids, sludge and wall scrapings removed and nothing put back. Irving prohibits skimming or partial cleaning. North Richland Hills says to call the city if the hauler does not open and clean every compartment. Get a manifest each time.
Fort Worth requires a 100 percent pump-out.[11] Houston has you sign the manifest to confirm the entire contents were removed, so check before you sign.[9] Southlake also says a sample port, if installed, is cleaned on the same schedule as the interceptor, and that lids must not be covered by landscaping or paving.[3] Southlake staff measure the grease layer in both compartments with a core sampler called a “sludge judge” during inspections.[3]
Line jetting is a separate service. It clears pipes but does not empty the trap; see pumping vs. hydro-jetting. For published prices, see grease trap cleaning cost (third-party ranges, labeled as such).
Can enzymes or bacteria replace grease trap pumping?
Not as a substitute for pumping. Austin prohibits enzymes, bacteria and other agents that let grease pass through the trap. Fort Worth and Plano forbid them without city approval, and Irving does not allow them in place of maintenance. Southlake bans emulsifying additives. Houston inspectors ask for invoices from a permitted biological pretreatment company, if you use one.
Austin explains the problem: these products temporarily liquefy grease, which then re-congeals further down the pipes.[2] Southlake says emulsifying agents may keep your own drain lines open but simply move the grease problem to the city main.[3]
Hot water is not a cleaning method. Southlake says flushing an interceptor with hot water, or using chemicals to dissolve or emulsify grease so it flows into the sewer, violates City Code Chapter 9.5, Article III. It also says not to send water above 110 °F to a hydromechanical interceptor, because it melts the grease and lets it bypass the unit.[3] Fort Worth lists hot-water flushing in place of pumping among things not to do.[11]
Can restaurant staff clean the grease trap themselves?
Only where your city allows it, and usually only for a small unit. Southlake lets an employee clean a hydromechanical interceptor: vacuum the contents with a dedicated wet/dry vacuum into sealed 5 to 10 gallon buckets, then have a permitted liquid waste hauler collect them with a manifest. Its gravity interceptors must be pumped by a city-registered hauler.
Source [3]
Southlake’s manual adds: absorbent such as kitty litter, floor dry or wood chips may be mixed in; clean after hours because of the smell; and wear rubber gloves and eye protection. A disposal manifest is still required and must be available for inspection.[3] Other cities may require a permitted hauler for every unit. San Antonio, for example, requires a SAWS-permitted hauler only for interceptors over 100 gallons.[17] Ask your sewer authority before staff open the unit.
What grease trap maintenance records should a restaurant keep?
Southlake recommends an on-site log of who cleaned the interceptor, the date, roughly how much waste came out and how it was disposed of. Keep the hauler's manifests too: five years in Houston, Fort Worth and Irving, three in Austin, Plano and Southlake, and two in Grand Prairie, Rowlett and North Richland Hills.
Source [3][9][11][6][2][13][18][19][15]
A simple log, with the fields Southlake names:
| Date | Who cleaned it (company, permit or truck no.) | Approx. waste removed | How the waste was disposed of | Manifest no. |
|---|---|---|---|---|
The first four columns are Southlake’s fields.[3] The manifest number column is our suggestion, so the log points to the paper record. Each city’s manifest rules are on grease trap manifests.
Moving into a space with an existing trap
Southlake’s April 2026 commercial submittal guidelines say an existing grease interceptor must be pumped and power-washed for a Public Works inspection when a new food business moves in.[20] Haltom City’s commercial welcome packet tells new tenants of an existing space to have a liquid waste hauler service the interceptor as soon as they receive a certificate of occupancy, and says records are kept on site at least five years. That packet is dated January 2022, so confirm current rules with the city.[21] The interceptor may also need an inspection; see grease trap inspections.
Why it matters: limits, lifespan and penalties
- Discharge limits. Austin sets an instantaneous limit of 200 milligrams per liter for fats, oils and grease (§ 15-10-23).[2] Houston’s BMP sheet says a trap discharging 400 mg/L or more draws enforcement, and that the final limit from December 2, 2023 is 200 mg/L.[1]
- Lifespan. Houston says mechanical grease traps typically last about 5 years and gravity grease traps about 10, and that traps deteriorate over time.[1] Treat that as Houston’s rule of thumb, not a guarantee.
- Penalties. In Austin each missed maintenance or record requirement is a separate violation, with possible fines and permit revocation.[2] Fort Worth lists penalties of up to $2,000 per violation per day.[11] Haltom City warns an unmaintained interceptor can close a business until pumping, cleanup and repairs are done.[21]
Related pages
Schedules and costs: the grease trap cleaning guide. Equipment types: grease trap vs. grease interceptor. Formulas and minimum sizes: grease trap sizing. Paperwork: manifests. Inspections: grease trap inspections. City rules and officially listed haulers: all cities. This page is not legal advice. Rules change, so confirm with your sewer authority or health department.
Sources
Sources checked .
- Houston Health Department, Best Management Practices for Food Establishments (PDF)
- Austin Water, Grease Trap Maintenance
- City of Southlake Public Works, Fats, Oils, and Grease (FOG) Manual (Adopted Jan. 2013; Revised Jan. 2020; DocumentCenter View/44323 FOG-MANUAL-June-2025; PDF modified June 13, 2025)
- City of North Richland Hills Consumer Health Division, List of Permitted Liquid Waste Transporters (Last Updated 06-25-2026; English and Spanish; DocumentCenter View/6118; read Nov. 6, 2026)
- Dallas Pretreatment and Laboratory Services Division, Grease Traps/Interceptors ordinance poster (PDF)
- City of Irving Ordinance ORD-2025-11144 amending Chapter 41 Water and Sewer Systems, Article VIII Liquid Waste Transport and Management (adopted 2025; Sec. 41-50 grease trap/interceptor duties)
- City of Grand Prairie Public Health and Environmental Quality, Grease Traps page (food service permits)
- Miami-Dade County Mayor, Report on Review of the County’s Fats, Oils, and Grease (FOG) Regulations, Implementation, and Enforcement (Sept. 18, 2026; Board agenda item 2(B)(8), Oct. 6, 2026)
- Houston Health Department, Waste Generator's Frequently Asked Questions
- Dallas Water Utilities, Liquid Waste Program
- City of Fort Worth Water, Grease Traps page
- City of Irving Water Utilities Environmental Compliance, Grease Interceptor/Trap Cleaning and Maintenance brochure
- City of Plano Ordinance adopting Article VIII, Liquid Waste Management, of Chapter 21 Utilities (Council agenda attachment; Sec. 21-362 grease trap evacuation; Sec. 21-381 transporter permits)
- City of Southlake Public Works, Fats, Oils, and Grease (FOG) Program (Ordinance 914; 90-day cleaning; 25% rule; permitted haulers)
- City of North Richland Hills, Waste Hauler Permit page (permits renewed annually; NRH trip ticket books; grease traps cleaned at least quarterly)
- U.S. Environmental Protection Agency, Controlling Fats, Oils, and Grease Discharges from Food Service Establishments (fact sheet)
- City of San Antonio, Fats, Oils and Grease ordinance, Chapter 34, Article 5, Division 4 (PDF posted by SAWS; 2011 adoption text, Secs. 34-527 to 34-529)
- City of Grand Prairie Public Health and Environmental Quality, Food For Thought newsletter, Winter 2024 (PDF; "Grease Trap Maintenance")
- City of Rowlett, Fats, Oils and Grease (FOG) in Food Service Establishments (90-day service, full evacuation, trip tickets kept two years, $50 inspection fee on FSE permit)
- City of Southlake Building Inspections, Commercial Submittal Guidelines April 2026 (existing grease interceptors must be pumped and power-washed for Public Works inspection at move-in)
- City of Haltom City, Commercial Welcome Packet (stormwater and FOG best management practices; grease interceptors pumped every 90 days, records kept 5 years; PDF dated January 2022)