Grease trap vs. grease interceptor: the difference, the two interceptor types, and how cities size them
Last updated .
What each term means where it is defined in law, how gravity and hydromechanical interceptors differ, Austin Water’s published sizing method, and the size rules in New Orleans, San Antonio and Miami-Dade. Every rule links to the authority that wrote it.
What is the difference between a grease trap and a grease interceptor?
Often they mean the same device. Austin Water says grease traps are also called grease interceptors. Where cities do draw a line, a trap is usually the smaller unit inside the kitchen and an interceptor the larger outdoor or underground tank. Austin and Miami-Dade split interceptors into gravity and hydromechanical types.
How each city defines the terms
| Place | What the source says |
|---|---|
| Austin, Texas | Grease traps, “also called grease interceptors,” separate fats, oils and grease and food solids from wastewater. Grease traps are typically large pre-cast concrete tanks of 250 to 10,000 gallons with two compartments. Hydromechanical grease interceptors use gravity separation aided by vented flow control and are typically single-compartment fiberglass or polyethylene units.[1] |
| New Orleans, Louisiana | Uses “grease retention unit” for any such device. A grease interceptor is the outdoor or underground type, normally of 40 pound capacity or more. A grease trap is typically an in-floor recessed unit, normally not less than 125 gallons; some older traps are under-sink or above-floor.[2] |
| San Antonio, Texas | The ordinance uses one word, “interceptor”: a device for collecting, containing or removing food wastes or fats, oils or grease from a waste stream before it enters the sewer. It must comply with City Code Chapter 24 and the International Plumbing Code as adopted by the city.[3] |
| Houston, Texas | The Health Department’s FAQ says “grease trap/interceptor” for a device that keeps oil, grease and other matter out of the city sewer. Dishwashers, two- and three-compartment sinks, mop sinks and floor drains flow into it.[4] |
| Miami-Dade County, Florida | Uses “FOG control device” and names two kinds: gravity grease interceptors (GGIs, concrete tanks) and hydromechanical grease interceptors (HGIs).[5] |
So the answer depends on where you are. In Houston and Austin the words are used for the same job. In New Orleans the difference is mostly location and size. When a contractor, hauler or inspector uses either word, ask which device they mean and what capacity it holds.
What is the difference between a gravity and a hydromechanical grease interceptor?
A gravity grease interceptor is a large tank, usually concrete with two compartments, that holds wastewater long enough for grease to float and solids to settle. A hydromechanical grease interceptor is a compact unit rated by flow in gallons per minute under the ASME A112.14.3 standard. Austin suits it to low-grease kitchens without dishwashers.
| Gravity grease interceptor (GGI) | Hydromechanical grease interceptor (HGI) | |
|---|---|---|
| How it is rated | By liquid holding capacity and retention time. Austin requires at least 7 minutes in the first compartment and 5 in the second at rated flow.[6] | By flow, in gallons or liters per minute, with a minimum grease capacity, under ASME A112.14.3.[7] Austin requires a rating of at least 75 gallons per minute.[6] |
| Build | Austin: two compartments (three for very large tanks), concrete or non-corrodible material, every compartment reachable for cleaning and inspection.[6] | Austin: non-corrodible material; units over 500 gallons need a 60/40 split between compartments.[6] |
| Where it fits | Austin requires two-compartment units with 12 minutes total retention for kitchens with dishwashers or wok stoves.[6] | Austin says HGIs generally suit low-grease shops such as small sandwich shops, coffee shops and bakeries that use disposable flatware and no automatic dishwasher. Larger HGI models are also permitted when site conditions are not ideal for a gravity interceptor.[6] Miami-Dade calls HGIs more efficient, with a smaller footprint.[5] |
| Septic systems | Miami-Dade’s report says that for kitchens on septic systems the state (Florida DEP) only allows gravity interceptors, and does not allow them indoors or under 750 gallons.[5] | Not accepted for kitchens on septic systems in Miami-Dade wellfield protection areas, per the same report.[5] |
ASME A112.14.3 describes four ways to install a hydromechanical unit: Type A and B with an external flow control (with or without an air vent) and directly connected, Type C directly connected with no external flow control, and Type D indirectly connected with no external flow control.[7] Austin requires Type D.[6] Austin’s FAQ also says vented flow control devices must be installed upstream to match the certified flow rate of an HGI.[1]
How is a grease trap sized?
Austin Water publishes a three-step method. Add up the fixture units of every sink and drain connected to the trap, multiply by 3 gallons per minute to get the flow rating, then multiply by 12 minutes for the minimum liquid capacity. Austin approves nothing under 100 gallons, and kitchens with a dishwasher need at least 500.
Source [6]
- Count fixture units. Austin assigns fixture units by fixture and drain size. For fixtures that drain through a floor sink or hub drain, compartment sinks and wok stoves count 4, 6 or 8 for a 2-, 3- or 4-inch trap arm. A dishwasher counts 6 or 8. Hand sinks and mop sinks count 2, 3 or 4. Directly connected hand sinks count 0. Garbage disposals and grinders are prohibited.[6]
- Flow rating = total fixture units × 3 gallons per minute.[6]
- Minimum liquid holding capacity (gallons) = flow rating × 12 minutes.[6]
Austin adds several conditions. Industrial Waste staff apply the formula along with professional judgment, often require a larger trap and only rarely approve a smaller one. Units under 100 gallons are not approved. Kitchens that use a dishwasher need at least 500 gallons. For indirect waste systems that use floor sinks and hub drains as receptors for dishwashers and compartment sinks, the fixture unit count is twice the floor sink or hub drain count. Fixtures carrying only clear water, such as cooler condensate, may drain through the trap but are not counted unless routed to a floor sink.[6]
This is Austin’s method, not a national one. It applies to kitchens that Austin Water regulates. Your approval letter, not this page, sets your size. Austin says it updated its interceptor policies in April 2021.[6]
How do other cities size grease interceptors?
New Orleans and San Antonio point to the International Plumbing Code instead of publishing their own formula. New Orleans also says dishwashers with booster heaters or water above 140 degrees Fahrenheit cannot drain through a unit smaller than 1,000 gallons. Every one of these cities wants the design approved before installation.
- New Orleans: new food businesses must install a grease interceptor unless granted a variance, sized under the International Plumbing Code, with site plans sealed by a Louisiana licensed professional engineer. Each chamber must be directly reachable from the surface. Where food waste grinders are installed, their waste goes directly to a grease vault. Inside traps on individual fixtures are allowed only where an outdoor interceptor is infeasible, with prior approval.[2]
- San Antonio: every sink, dishwasher, drain or fixture that can carry grease must discharge to an interceptor that complies with City Code Chapter 24 and the International Plumbing Code as adopted by the city.[3]
- Miami-Dade: to keep an existing device installed before the 2018 FOG ordinance, a business shows it is in good condition and properly sized, with calculations based on the device and the business’s grease load; existing hydromechanical units have had to meet 99 percent removal efficiency. The county’s September 2026 report proposes dropping that 99 percent rule for existing units in good condition. That is a proposal, not the rule.[5]
- Houston: the Health Department FAQ we cite does not state a size rule, so none is given here.[4]
Is a grease interceptor cleaned differently from a grease trap?
Both get pumped out by a permitted hauler, and the city schedule usually applies to whatever device you have. Miami-Dade is the exception we found: older permits there were set at 30 days for hydromechanical interceptors and 90 days for concrete gravity tanks. San Antonio requires a SAWS-permitted hauler for interceptors over 100 gallons.
San Antonio’s schedule applies to every interceptor: pump at least every 90 days, and within two working days once 25 percent of the wetted height holds grease or solids. Units of 100 gallons or less may be pumped by a SAWS-permitted hauler, while larger ones must be.[3] Austin and Houston schedules are on the cleaning guide. Austin says its sizing rules assume gravity separation, and adding enzymes or chemicals to the trap is prohibited.[6] Whichever kind you have, ask for a full pump-out and a manifest each visit; see grease trap manifests.
Can I buy a grease interceptor before the city approves it?
Not before the city signs off. Austin Water says not to buy a grease trap or interceptor until building plan approval and an Industrial Waste approval letter specify the size and design, because an unapproved unit may be rejected and replaced. New Orleans requires its Plumbing Department to approve the design before installation.
- Get your sewer authority’s size and design in writing first (Austin: the Industrial Waste approval letter).[6]
- Ask whether a gravity or hydromechanical unit is allowed for your kitchen, and whether a dishwasher or wok stove changes that.[6]
- Plan access. New Orleans requires every chamber to be reachable from the surface and kept clear of obstructions.[2]
- Austin publishes an approved manufacturers list and says those manufacturers are familiar with its criteria.[6]
- Remember the yearly inspection where it applies: San Antonio and New Orleans require one on the emptied interceptor. See grease trap inspections.
Related pages
Every sizing formula and minimum size we have found, city by city: grease trap sizing.
How often to pump and what it costs: the grease trap cleaning guide. Day-to-day upkeep: grease trap maintenance. City rules and officially listed haulers: Houston, Austin, New Orleans, Miami, Nashville, Tampa, Jacksonville, Cincinnati and Louisville, Broward County, Hampton Roads, Pinellas County, Gainesville, Baton Rouge, Corpus Christi, Bradenton, Denton, Brownsville, Tulsa, McAllen, Oklahoma City, Williamsburg, Charleston. This page is not engineering or legal advice; a licensed plumber or engineer and your sewer authority decide your design.
Sources
Sources checked .
- Austin Water, Pretreatment Frequently Asked Questions
- Sewerage & Water Board of New Orleans, Plumbing Code Section 16.5, Rules Governing the Discharge into the Public Sanitary Sewerage System From Grease Traps and Grease Interceptors (PDF, February 2016 version linked from the S&WB pretreatment page)
- City of San Antonio, Fats, Oils and Grease ordinance, Chapter 34, Article 5, Division 4 (PDF posted by SAWS; 2011 adoption text, Secs. 34-527 to 34-529)
- Houston Health Department, Waste Generator's Frequently Asked Questions
- Miami-Dade County Mayor, Report on Review of the County’s Fats, Oils, and Grease (FOG) Regulations, Implementation, and Enforcement (Sept. 18, 2026; Board agenda item 2(B)(8), Oct. 6, 2026)
- Austin Water, Grease Trap Sizing & Design Criteria (interceptor policies updated April 2021; page checked October 29, 2026)
- ASME A112.14.3, Hydromechanical Grease Interceptors (ASME preview excerpt: scope, definitions and installation Types A to D)