Grease trap manifests: what they are, who signs, how long to keep them

Last updated .

The manifest, or trip ticket, is the paper trail for every grease trap pump-out. This page explains what it must show, who signs it, how the copies move, and how long Houston, Austin, Texas, New Orleans, Miami-Dade, Georgia and Salt Lake City say to keep it, with a link to each rule.

What is a grease trap manifest?

A grease trap manifest, which Texas also calls a trip ticket, is the multi-part form the hauler fills out at every pump-out. It records who generated the waste, how much was removed, and where it was disposed. Houston calls it an official government document. You sign it, keep your copy, and show it to inspectors.

Source [1][2]

Houston’s Health Department describes the waste manifest as “an official government document that must be completed every time your interceptor is cleaned.”[2] The Texas Commission on Environmental Quality says haulers must give customers a completed copy of their multi-part trip ticket, “also referred to as a waste manifest.”[1]

How long do I have to keep grease trap manifests?

It depends on the local rule. Houston requires five years on site and Salt Lake City five years for cleaning records. Austin, New Orleans and Georgia require three years. Texas makes haulers keep trip tickets five years. The Miami-Dade pages we read do not state a period for restaurants, so check your county permit.

Source [2][3][4][5][6][7]

Manifest and cleaning-record retention, as each authority states it
PlaceHow long the kitchen keeps itOther record rules
Houston, TexasAt least 5 years, on site, from the clean-out date (white and yellow copies).[2]Keep the generator copy and the returned generator copy on site for five years. Inspectors ask for five years of manifests.[8][2]
Austin, Texas3 years, on site (§15-10-165). The pretreatment FAQ words it as “up to three years.”[4][9]Trip-ticket manifest documentation must follow §15-10-197.[9]
Texas (state rule for haulers)The state guidance tells kitchens to check with local authorities for how long to keep records.[1]Transporters keep trip tickets for 5 years.[7]
New Orleans, LouisianaCleaning records kept on site for a continuous period of 3 years.[5]Records show date and time of cleaning, quantity removed and the company. The cleaning company sends copies to the Sewerage & Water Board monthly.[5]
Miami-Dade County, FloridaNot stated on the county pages we read. Check your Grease Discharge Operating permit.[10]Each load goes on a Single Load manifest and is reported monthly in the county eManifest system.[11][10]
Georgia (statewide, including Atlanta)3 years, at the originator’s principal place of business.[6]One manifest per location serviced. The transporter also keeps copies 3 years.[6]
Salt Lake City, UtahAt least 5 years, on site, for all grease control equipment maintenance, cleaning and repairs.[3]Records must be readily available for inspection on request.[3]

Salt Lake City and Georgia are not city pages on this site yet, because we have not found an official list of grease haulers there that we can republish. Their record rules are included because they are published by the authority.

Who signs a grease trap manifest?

Three parties sign. The restaurant, called the generator, signs to confirm the details and, in Houston, that the entire contents were removed. The hauler signs the transporter section. The disposal or receiving facility signs to acknowledge receipt. Texas and Georgia rules then require the hauler to return a fully signed copy to the restaurant.

Source [2][7][6]

  1. At the pump-out, the hauler fills in its own details and yours. In Texas, one part of the five-part trip ticket is handed to you at pickup with the generator and transporter information completed.[7] In Houston you sign the top portion to attest that the entire content of the trap was removed.[2]
  2. At the disposal site, the receiving facility’s representative signs to acknowledge receipt and the amount received. In Texas, one part stays with the facility and one with the transporter.[7] Georgia’s rule says the transporter signs its section and the disposal operator completes and signs the receiver section, keeping a copy.[6]
  3. Back to you: Texas requires the transporter to return a copy to the generator within 15 days after the waste is received at the disposal or processing facility.[7] Georgia requires a copy with the disposal operator’s signature within 30 days, and the originator signs that received manifest and keeps it three years.[6]
  4. To the local authority, if one is needed: Texas reserves one part of the trip ticket for it.[7] New Orleans has the cleaning company send copies of cleaning records monthly.[5] Miami-Dade uses its eManifest system.[10]

What must a Texas grease trap trip ticket show?

Under 30 TAC 312.145, a Texas trip ticket must show the transporter's name, address, phone and state registration number; the generator's name, signature, address, phone and pickup date; the waste type and amount; who collected and deposited it; where and when it was deposited; the receiving facility's signature; and the trap's volume.

Source [7]

The rule text, 30 Texas Administrative Code §312.145(a), lists eight items. We read it on Cornell’s Legal Information Institute, which republishes the Texas rules.[7]

  1. Name, address, telephone number and state registration number of the transporter.
  2. Name, signature (or electronic signature), address and telephone number of the person who generated the waste, and the date collected.
  3. Type and amount of waste collected or transported.
  4. Name and signature of the people collecting, transporting and depositing the waste.
  5. Date and place where the waste was deposited.
  6. Identification of the receiving facility: permit or site registration number, location and operator.
  7. Name and signature of the facility’s on-site representative, acknowledging receipt and the amount received.
  8. The volume of the grease trap, grit trap or septic tank.

The same rule says the trip ticket has five parts, that the receiving facility must note significant discrepancies (for liquid waste, any variation greater than 15 percent in gallons), and that a local ordinance with equivalent or stricter records can satisfy the state requirement.[7] Texas guidance says to use a sludge transporter registered with the commission to pump and transport grease trap waste.[1]

Check before you sign

The Texas Commission on Environmental Quality says the generator should check these on the trip ticket, take note of the planned disposal site, and then sign.[1]

Local details

Houston

The Health Department tells kitchens, before the trap is cleaned, to inspect and verify that it is clean and completely empty before signing, to make sure the sample well is clean and the correct capacity is noted, to sign the “generator” portion, to retain the generator copy from the transporter, and to return the generator copy within 15 days of the pump-out. It says to keep the generator and returned generator copies on site for five years.[8] During an inspection, the investigator asks for the white and yellow copies of waste manifests for the past five years.[2]

Austin

Austin Water says manifest records provided by the liquid waste hauler after each pump-out must be kept on site for three years, and links an example manifest from its grease trap maintenance page. If a manifest says the trap needs repair, the city says to have it serviced immediately.[4] Haulers buy manifest books from Austin Water’s Utility Compliance Services Division, and the waste must go to an approved receiving station.[9]

New Orleans

Section 16.5 of the Sewerage & Water Board plumbing code says property owners and food service establishments must keep cleaning and pumping receipts showing the date and time the interceptor was cleaned, the quantity of grease and materials removed, and the company or agent that did it. Those records stay on site for a continuous period of three years, and the cleaning company (or the kitchen, if no permitted hauler was used) submits copies monthly to the board’s Environmental Affairs office. The version linked from the board’s pretreatment page is dated February 2016.[5]

How does the Miami-Dade grease trap eManifest work?

Miami-Dade brown grease transporters must record each load on the county's Single Load manifest form and report it electronically every month in the eManifest system. Kitchens with a GDO permit class OP or GENOP must submit the eManifest by the 20th of the month the grease control device is cleaned. Inspectors review these records.

Source [11][10][12]

The county’s September 2026 report says each pump-out generates a FOG Single Load Liquid Waste Transporter eManifest that also records observed corrosion or other tank damage and whether the tank is breached. Its annual inspections review pump-out receipts and e-manifest records, and failure to provide logs and e-manifest reports results in enforcement.[12]

Georgia, including Atlanta

Georgia regulates grease trap haulers statewide under State Rule 391-3-6-.24, which the Environmental Protection Division says provides a commercial waste transporter permit accepted statewide.[13] The rule text says every originator, transporter and disposal site must take part in keeping manifests; that a manifest has originator, receiver and transporter sections; and that each keeps copies for three years.[6] We read the rule on a copy posted by the Southeastern FOG Alliance, an independent group the state agency points to, because the state’s official rules site blocked our request.

What if the hauler never returns my signed copy?

Ask the hauler for it. Texas requires the transporter to return the signed copy within 15 days after the waste reaches the disposal facility, and Houston tells kitchens to return the generator copy within 15 days of the pump-out. Georgia allows 30 days. Texas also says to contact the receiving facility to confirm it received your waste.

Source [7][8][6][1]

Texas guidance reminds kitchens that the generator is responsible for its waste until it reaches the proper disposal facility, and could be held responsible for improper disposal. It says to contact the receiving facility listed on your returned copy to verify its authorization and receipt of your waste.[1]

Pump-out schedules and hauler permits are in the grease trap cleaning guide, which also has Houston’s inspection document checklist. Annual interceptor inspections and what inspectors check: grease trap inspections. City rules and officially listed haulers: Houston, Austin, New Orleans, Miami, Nashville, Tampa, Jacksonville, Cincinnati and Louisville, Broward County, Hampton Roads, Pinellas County, Gainesville, Baton Rouge, Corpus Christi, Bradenton, Denton, Brownsville, Tulsa, McAllen, Oklahoma City, Williamsburg, Charleston. Used fryer oil is collected separately and has its own records; see used cooking oil pickup.

Questions on this page

Each answer above is also the short answer in its section: what a manifest is, who signs, how long to keep it, Texas trip tickets, the Miami-Dade eManifest and a missing copy. This page is not legal advice. Rules change, so confirm with your sewer authority or health department.

Request quotes from local haulers

Free. Tell us what you need and we will pass it to haulers that serve your area.

See our privacy page for what we collect and who sees it.

Sources

Sources checked .

  1. Texas Commission on Environmental Quality, RG-389: Waste from Grease Traps, Grit Traps, and Septic Tanks (PDF)
  2. Houston Health Department, Waste Generator's Frequently Asked Questions
  3. Salt Lake City Public Utilities, Wastewater Pretreatment Fats, Oils and Grease (FOG)
  4. Austin Water, Grease Trap Maintenance
  5. Sewerage & Water Board of New Orleans, Plumbing Code Section 16.5, Rules Governing the Discharge into the Public Sanitary Sewerage System From Grease Traps and Grease Interceptors (PDF, February 2016 version linked from the S&WB pretreatment page)
  6. Georgia Rule 391-3-6-.24, Regulation of Commercial Waste Originators, Pumpers, Transporters, Processors, and Disposal Facilities (rule text as posted by the Southeastern FOG Alliance, a third-party nonprofit; PDF)
  7. 30 Texas Administrative Code §312.145, Transporters—Recordkeeping (trip tickets), as published by Cornell LII (third-party copy of the state rule)
  8. Houston Health Department, Special Waste Generators (cites City Code Sec. 47-512(b))
  9. Austin Water, Pretreatment Frequently Asked Questions
  10. Miami-Dade County, Grease Discharge Operating Permit eManifest reporting page
  11. Miami-Dade County, Liquid Waste Transporter Permit (Department of Regulatory and Economic Resources)
  12. Miami-Dade County Mayor, Report on Review of the County’s Fats, Oils, and Grease (FOG) Regulations, Implementation, and Enforcement (Sept. 18, 2026; Board agenda item 2(B)(8), Oct. 6, 2026)
  13. Georgia Environmental Protection Division, Fats, Oils, and Grease (FOG) (State Rule 391-3-6-.24)
Get quotes